INGECON SUN STORAGE 10-15-20-30TL M Specifications
| Category | 10TL M | 15TL M | 20TL M | 30TL M |
|---|---|---|---|---|
| BATTERY INPUT (DC) | ||||
| Voltage range | 150 – 600 V | 150 – 800 V | 150 – 800 V | 150 – 800 V |
| Nominal battery voltage | 200 – 600 V | 200 – 800 V | 200 – 800 V | 200 – 800 V |
| Maximum charge/discharge current | 50A / 50A | 50A / 50A | 50A / 50A | 50A / 50A |
| Maximum charge/discharge power | 15,000 / 10,500 W | 18,000 / 15,000 W | 24,000 / 20,000 W | 30,000 / 30,000 W |
| Maximum voltage | 600 V | 800 V | 800 V | 800 V |
| PV INPUT (DC) | ||||
| Maximum PV field power | 15,000 W | 22,500 W | 30,000 W | 45,000 W |
| MPPT voltage range | 160 – 950 V | 160 – 950 V | 160 – 950 V | 160 – 950 V |
| Maximum input voltage | 1,000 V | 1,000 V | 1,000 V | 1,000 V |
| Maximum current per MPPT (input 1 / input 2) | 20A / 30A | 30A / 30A | 30A / 30A / 30A | 30A / 30A / 30A |
| Maximum short-circuit current (input 1 / input 2) | 30A / 40A | 40A / 40A | 40A / 40A / 40A | 40A / 40A / 40A |
| Number of MPP trackers | 2 | 2 | 2 | 2 |
| Number of inputs per MPP tracker | 1 / 2 | 2 / 2 | 2 / 2 / 2 | 2 / 2 / 2 |
| GRID INPUT (AC) | ||||
| Nominal voltage | 400 V | 400 V | 400 V | 400 V |
| Voltage range | 277 – 520 V (Adjustable) | 277 – 520 V (Adjustable) | 277 – 520 V (Adjustable) | 277 – 520 V (Adjustable) |
| Nominal frequency | 50 / 60 Hz | 50 / 60 Hz | 50 / 60 Hz | 50 / 60 Hz |
| Grid type | TN | TN | TN | TN |
| Nominal power | 10 kW | 15 kW | 20 kW | 30 kW |
| Maximum temperature for nominal power | 45ºC | 45ºC | 45ºC | 45ºC |
| Power percentage at 50ºC | 80% | 80% | 80% | 80% |
| Nominal current | 3*15.2A | 3*22.8A | 3*30.4A | 3*45.6A |
| Power factor | >0.99 Nominal power (adjustable 0.8 LG-0.8 LD) | >0.99 Nominal power (adjustable 0.8 LG-0.8 LD) | >0.99 Nominal power (adjustable 0.8 LG-0.8 LD) | >0.99 Nominal power (adjustable 0.8 LG-0.8 LD) |
| Adjustable power factor | YES | YES | YES | YES |
| THD | <3%< /td> | <3%< /td> | <3%< /td> | <3%< /td> |
| CRITICAL LOAD OUTPUT (AC) | ||||
| Nominal output voltage | 400 V | 400 V | 400 V | 400 V |
| Nominal output frequency | 50 / 60 Hz | 50 / 60 Hz | 50 / 60 Hz | 50 / 60 Hz |
| Nominal output power | 10 kW | 15 kW | 20 kW | 30 kW |
| Nominal output current | 3*15.2A | 3*22.8A | 3*30.4A | 3*45.6A |
| THDV | <3% (R load), 5% (RCD load) | <3% (R load), 5% (RCD load) | <3% (R load), 5% (RCD load) | <3% (R load), 5% (RCD load) |
| FEATURES | ||||
| Maximum efficiency | 98.4% | 98.4% | 98.4% | 98.4% |
| Euro efficiency | 97.9% | 97.9% | 97.9% | 97.9% |
| Maximum efficiency (BAT) | 98.0% | 98.0% | 98.0% | 98.0% |
| GENERAL INFORMATION | ||||
| Cooling system | Natural ventilation | Natural ventilation | Forced ventilation | Forced ventilation |
| Standby consumption | <20 W | <20 W | <20 W | <20 W |
| Nighttime consumption | <10 W | <10 W | <10 W | <10 W |
| Ambient temperature | -25ºC to 60ºC | -25ºC to 60ºC | -25ºC to 60ºC | -25ºC to 60ºC |
| Relative humidity (non-condensing) | 0 – 100% | 0 – 100% | 0 – 100% | 0 – 100% |
| Protection class | IP65 | IP65 | IP65 | IP65 |
| CE marking | Yes | Yes | Yes | Yes |
| Noise emissions | <30 dB | <30 dB | 45 dB | 45 dB |
| Maximum altitude without derating | 4,000 m | 4,000 m | 2,000 m | 2,000 m |
| EMC and safety standards | EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-2, EN 61000-3-3, EN 61000-3-11, EN 61000-3-12, EN 62109-1, EN 62109-2, IEC62103, EN 50178, FCC Part 15, AS3100 | EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-2, EN 61000-3-3, EN 61000-3-11, EN 61000-3-12, EN 62109-1, EN 62109-2, IEC62103, EN 50178, FCC Part 15, AS3100 | EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-2, EN 61000-3-3, EN 61000-3-11, EN 61000-3-12, EN 62109-1, EN 62109-2, IEC62103, EN 50178, FCC Part 15, AS3100 | EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-2, EN 61000-3-3, EN 61000-3-11, EN 61000-3-12, EN 62109-1, EN 62109-2, IEC62103, EN 50178, FCC Part 15, AS3100 |
| Grid connection standards | RD1699/2011, DIN V VDE V 0126-1-1, EN 50438, CEI 0-16 Ed. III, CEI 0-21, VDE-AR-N 4105:2011-08, G59/2, G83/2(10), P.O.12.3, AS4777.2, AS4777.3, IEC 62116, IEC 61727, UNE 206007-1, ABNT NBR 16149, ABNT NBR 16150, South African Grid code, Chilean Grid Code, Romanian Grid, Code, Ecuadorian Grid Code, Peruvian Grid code, IEEE 929, Thailand MEA & PEA requirements, DEWA (Dubai) Grid Code, Jordan Grid Code | RD1699/2011, DIN V VDE V 0126-1-1, EN 50438, CEI 0-16 Ed. III, CEI 0-21, VDE-AR-N 4105:2011-08, G59/2, G83/2(10), P.O.12.3, AS4777.2, AS4777.3, IEC 62116, IEC 61727, UNE 206007-1, ABNT NBR 16149, ABNT NBR 16150, South African Grid code, Chilean Grid Code, Romanian Grid, Code, Ecuadorian Grid Code, Peruvian Grid code, IEEE 929, Thailand MEA & PEA requirements, DEWA (Dubai) Grid Code, Jordan Grid Code | RD1699/2011, DIN V VDE V 0126-1-1, EN 50438, CEI 0-16 Ed. III, CEI 0-21, VDE-AR-N 4105:2011-08, G59/2, G83/2(10), P.O.12.3, AS4777.2, AS4777.3, IEC 62116, IEC 61727, UNE 206007-1, ABNT NBR 16149, ABNT NBR 16150, South African Grid code, Chilean Grid Code, Romanian Grid, Code, Ecuadorian Grid Code, Peruvian Grid code, IEEE 929, Thailand MEA & PEA requirements, DEWA (Dubai) Grid Code, Jordan Grid Code | RD1699/2011, DIN V VDE V 0126-1-1, EN 50438, CEI 0-16 Ed. III, CEI 0-21, VDE-AR-N 4105:2011-08, G59/2, G83/2(10), P.O.12.3, AS4777.2, AS4777.3, IEC 62116, IEC 61727, UNE 206007-1, ABNT NBR 16149, ABNT NBR 16150, South African Grid code, Chilean Grid Code, Romanian Grid, Code, Ecuadorian Grid Code, Peruvian Grid code, IEEE 929, Thailand MEA & PEA requirements, DEWA (Dubai) Grid Code, Jordan Grid Code |