| Model |
A0030230E1SH |
A0070230E1SH |
A0110400E1SH |
A0220400E1SH |
| Product Name |
Single Phase Socket 3.7KW |
Single Phase Socket 7.3KW |
Three Phase Socket 11KW |
Three Phase Socket 22KW |
| Input/Output |
| Rated Power |
3.7KW |
7.3KW |
11KW |
22KW |
| Rated Input Voltage |
230Vac |
230Vac |
400Vac |
400Vac |
| Input Voltage Range |
230Vac±15% |
230Vac±15% |
400Vac±15% |
400Vac±15% |
| Rated Output Current |
16A |
32A |
16A |
32A |
| Output Current Range |
6A~16A |
6A~32A |
6A~16A |
6A~32A |
| Rated Frequency |
50Hz/60Hz |
50Hz/60Hz |
50Hz/60Hz |
50Hz/60Hz |
| Grid Architecture |
TT/TN-S/TN-C-S |
TT/TN-S/TN-C-S |
TT/TN-S/TN-C-S |
TT/TN-S/TN-C-S |
| Charging Interface |
Type2 socket, Type 2s socket (Optional) (5m/7m 2plug Cable Optional) |
Type2 socket, Type 2s socket (Optional) (5m/7m 2plug Cable Optional) |
Type2 socket, Type 2s socket (Optional) (5m/7m 2plug Cable Optional) |
Type2 socket, Type 2s socket (Optional) (5m/7m 2plug Cable Optional) |
| Connection Mode |
Case B |
Case B |
Case B |
Case B |
| Protection |
| Leakage Current Protection |
AC 30mA + DC 6mA |
AC 30mA + DC 6mA |
AC 30mA + DC 6mA |
AC 30mA + DC 6mA |
| Surge Protection |
Support |
Support |
Support |
Support |
| Overvoltage Protection |
Support |
Support |
Support |
Support |
| Undervoltage Protection |
Support |
Support |
Support |
Support |
| Overcurrent Protection |
Support |
Support |
Support |
Support |
| Grounding Protection |
Support |
Support |
Support |
Support |
| Short Circuit Protection |
Support |
Support |
Support |
Support |
| Over Temperature Protection |
Support |
Support |
Support |
Support |
| General Data |
| Dimension (W*H*D) |
170X393X145 mm |
170X393X145 mm |
170X393X145 mm |
170X393X145 mm |
| Weight |
4.6kg |
4.6kg |
5.7kg |
4.6kg |
| Installation Mode |
Wall Mounting (Column Optional) |
Wall Mounting (Column Optional) |
Wall Mounting (Column Optional) |
Wall Mounting (Column Optional) |
| IP Degree |
IP65 |
IP65 |
IP65 |
IP65 |
| IK Degree |
IK10 |
IK10 |
IK10 |
IK10 |
| Cooling |
Natural Cooling |
Natural Cooling |
Natural Cooling |
Natural Cooling |
| Working Temperature |
-30℃ ~ 50℃ |
-30℃ ~ 50℃ |
-30℃ ~ 50℃ |
-30℃ ~ 50℃ |
| Storage Temperature |
-40℃ ~ 70℃ |
-40℃ ~ 70℃ |
-40℃ ~ 70℃ |
-40℃ ~ 70℃ |
| Working Humidity |
5% ~ 95% RH |
5% ~ 95% RH |
5% ~ 95% RH |
5% ~ 95% RH |
| Working Altitude |
≤2000m |
≤2000m |
≤2000m |
≤2000m |
| Working Noise |
0dB |
0dB |
0dB |
0dB |
| Standby Power |
<5W |
<5W |
<5W |
<5W |
| User Indicator |
LED+APP |
LED+APP |
LED+APP |
LED+APP |
| Networking Mode |
Bluetooth; Ethernet; Wi-Fi/4G (Optional) |
Bluetooth; Ethernet; Wi-Fi/4G (Optional) |
Bluetooth; Ethernet; Wi-Fi/4G (Optional) |
Bluetooth; Ethernet; Wi-Fi/4G (Optional) |
| User Authorization |
Free Charging, RFID, MyLivoltek APP(Bluetooth & Remote & Schedule) |
Free Charging, RFID, MyLivoltek APP(Bluetooth & Remote & Schedule) |
Free Charging, RFID, MyLivoltek APP(Bluetooth & Remote & Schedule) |
Free Charging, RFID, MyLivoltek APP(Bluetooth & Remote & Schedule) |
| Charging Mode |
Fixed, Demand Response |
Fixed, Demand Response |
Fixed, Demand Response |
Fixed, Demand Response |
| Power Management |
Support |
Support |
Support |
Support |
| Firmware Update |
Local / OTA |
Local / OTA |
Local / OTA |
Local / OTA |
| Electricity Metering |
Support |
Support |
Support |
Support |
| Save Charging Record When Power Off |
Support |
Support |
Support |
Support |
| External Communication |
RS485 / CAN |
RS485 / CAN |
RS485 / CAN |
RS485 / CAN |
| Communication Protocol |
LIVOLTEK Protocol / OCPP 1.6J |
LIVOLTEK Protocol / OCPP 1.6J |
LIVOLTEK Protocol / OCPP 1.6J |
LIVOLTEK Protocol / OCPP 1.6J |
| Standard |
| EMC |
IEC-61851-21-2-2018 |
IEC-61851-21-2-2018 |
IEC-61851-21-2-2018 |
IEC-61851-21-2-2018 |
| Safety |
IEC-61851-1-2017 |
IEC-61851-1-2017 |
IEC-61851-1-2017 |
IEC-61851-1-2017 |